Gea Plate Heat Exchanger Plate Replacement Vt40

Product Details
Customization: Available
Customized: Customized
Certification: CE, ISO, RoHS
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (9)
  • Gea Plate Heat Exchanger Plate Replacement Vt40
  • Gea Plate Heat Exchanger Plate Replacement Vt40
  • Gea Plate Heat Exchanger Plate Replacement Vt40
  • Gea Plate Heat Exchanger Plate Replacement Vt40
  • Gea Plate Heat Exchanger Plate Replacement Vt40
  • Gea Plate Heat Exchanger Plate Replacement Vt40
Find Similar Products

Basic Info.

Model NO.
304/316/TI
Sectional Shape
Square
Material
Stainless Steel
Transport Package
Wooden Case
Specification
Customized
Trademark
DGXT OR OEM
Origin
China
HS Code
84165000
Production Capacity
100000pieces/Year

Product Description

                              Gasketed Plate Heat Exchanger

Gasketed plate heat exchangers are efficient heat exchange devices formed by a series of corrugated thin metal sheets and gaskets. The hot and cold fluids between the plates are separated by sealing gaskets so that they flow independently in the flow channels on both sides.

 

The heat transfer coefficient of gasketed plate heat exchangers is 3-5 times higher than that of the shell and tube heat exchanger because the hot and cold fluids can reach a high degree of turbulence when they flow in the plate channels which have certain corrugated shapes on the plate surface.  

Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40
Gasketed Plate Heat Exchanger Work


 

Gasketed plate heat exchangers are a type of heat exchanger that uses a series of thin metal plates with gaskets between them to transfer heat between two fluids. The two fluids flow through the heat exchanger in separate channels, with the hot fluid flowing through one set of channels and the cold fluid flowing through the other set of channels.

 

As the two fluids flow through the heat exchanger, heat is transferred from the hot fluid to the cold fluid through the thin metal plates. The gaskets between the plates help to create a seal between the two fluids, preventing them from mixing and allowing for efficient heat transfer.

 

The design of the gasketed plate heat exchangers allows for a large amount of heat transfer to occur in a relatively small space, making it a very efficient and compact heat exchanger. The heat transfer efficiency can also be improved by adjusting the flow rate, temperature, and other parameters of the fluids flowing through the heat exchanger.

 

Gasketed plate heat exchangers are commonly used in a variety of industrial and commercial applications, including HVAC systems, refrigeration, food processing, and chemical processing

Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40

Gasketed Plate Heat Exchanger Structure

 

Gasketed plate heat exchanger is mainly composed of plates, sealing gaskets, fixed plates, movable plates, carrying bars, guiding bars, columns, support columns tightening bolts and nuts, frame feet, etc.

 

Advantages of Gasketed Plate Heat Exchanger

 

1) High heat exchange efficiency and low operating cost - Compared with shell-and-tube heat exchanger, its heat exchange effect is 3-5 times.

2) Compact design - Small footprint.

3) Easy to install - Occupying only 1/5 to 1/8 of the space required by shell-and-tube heat exchanger.

3) Convenient maintenance - Easy to disassemble and clean.

4) Convenient expansion - Open the heat exchanger to increase the number of plates.

5) The NTU value is large - The minimum temperature difference can be 1 degree.

6) Reliable - At HFM, we strictly adhere to the highest standards of quality and safety, ensuring all of our products meet the rigorous. requirements of GRG, FDA, and SGS certifications.
Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40Gea Plate Heat Exchanger Plate Replacement Vt40

Gasketed Plate and Frame Heat Exchanger

 

1) The frames are put together. It consists of a fixed and moveable frame plate, top carryings bar, bottom guiding bars, tightening bolt, support column, and frame foot. The end plate is the first plate to be hung in the frame.

2) Then, the plate, according to the plate specification is placed between the frames, within the upper carrying bar and the lower guiding bar.

3) Lastly, the tightening bolts are installed to tighten the space between the fixed and movable frames using a spanner or a hydraulic wrench to a predetermined level depending on the model and number of plates of that plate heat exchanger.

 

The gasket plate heat exchanger (GPHE) utilizes corrugated plates located between the frame and pressure plates to provide an expansive heat transfer area. The gaskets act as seals between the plates, allowing for the counter-current flow of fluids through the exchanger, resulting in highly efficient thermal performance and a close temperature approach between the entering and exiting service mediums.

 

For heat-sensitive or viscous media, cold fluid is introduced to the hot fluid, reducing the risk of overheating or freezing. The plates come in various pressing depths, chevron-angled patterns, and corrugated shapes, all specifically designed to optimize performance based on the application.

 

The distribution area ensures even fluid flow across the entire heat transfer surface to avoid stagnant zones that may lead to fouling. High flow turbulence between plates results in enhanced heat transfer and pressure drop. HFM offers customizable thermal designs to suit a variety of applications and provide the greatest thermal performance with minimal pressure drop.


Gea Plate Heat Exchanger Plate Replacement Vt40

Basic Parameters of Gasketed Plate Heat Exchanger

 

Plate Materials:

Stainless Steel:  304L, 316L,904L

Special Metals: 254SMO, Hastelloy 276, Titanium, Nickel200/201 

 

Gasket Materials:

NBR, NBR-HT, EPDM, EPDM-HT, Viton,CR

 

Test Parameters:

Design Pressure: Max 25bar

Design Temperature: -20~180ºC

KEYWORDS:
commercial air exchanger
small shell and tube heat exchanger
mueller accu therm plate heat exchanger
steam plate heat exchanger
heat exchanger heating system
alfa laval shell and tube heat exchanger
steam to hot water heat exchanger
bryant heat exchanger
kuuma marine water heater
grainger heat exchanger
hydraulic oil heat exchanger
plate heat exchangers for sale
heat exchanger brush
air heat exchanger for house
domestic hot water heat exchanger
sondex as
wood burning fireplace heat exchanger
large heat exchanger
vevor heat exchanger
spiral tube heat exchanger
plate and frame heat exchanger manufacturers
wood burner heat exchanger
secespol heat exchanger
marine oil cooler heat exchanger
thermaline heat exchanger
exchanger types
itt plate heat exchanger
worcester bosch heat exchanger cost


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier