Cooler Heat Exchanger for Air Conditioning Heating System

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (9)
  • Cooler Heat Exchanger for Air Conditioning Heating System
  • Cooler Heat Exchanger for Air Conditioning Heating System
  • Cooler Heat Exchanger for Air Conditioning Heating System
  • Cooler Heat Exchanger for Air Conditioning Heating System
  • Cooler Heat Exchanger for Air Conditioning Heating System
  • Cooler Heat Exchanger for Air Conditioning Heating System
Find Similar Products
  • Overview
  • Detailed Photos
Overview

Basic Info.

Model NO.
S41/42, S62, S86, S110
Certification
CE, ISO
Application
Heater, Cooler, Vaporizer, Condenser
Principle
Recuperative Heat Exchanger
Style
Plate Type
Material
Stainless Steel
Gasket
EPDM/NBR
Core
Plate
Frame Material
Carbon, SS304, SS316
Transport Package
Plywood Case
Specification
Stainless Steel SS316L/0.5
Trademark
DGXT OR OEM
Origin
China
HS Code
84195000
Production Capacity
100000pieces/Year

Product Description

Manufacturers customized stainless steel heat exchanger boiler plate radiator dedicated plate heat exchanger

     The frame includes a fixed compression plate and a movable compression plate, which are supported by the upper guide rod and the lower guide rod, and have a pillar at the other end. The two mediums flow into the respective channels consisting of corrugated plates through the flange holes on the fixed (or movable) compression plate, and the medium flows out from the flange holes on the fixed (or movable) compression plate after the heat exchange. The same fixed pressure plate, movable pressure plate, pillar and guide are all low carbon steel. Considering the user's various requirements, there are many types of frame designs, including the double-supported frame type and the commonly used floor type.

     Heat transfer plates are one of the core components of plate heat exchangers. The corrugated sheet is formed by pressing, and the reasonable corrugated design increases the effective heat transfer area of the sheet, so that the fluid forms turbulence when passing along the corrugation, which strengthens the heat transfer process. A sealing gasket is arranged on the sealing groove of the corrugated plate, and the sealing gasket is designed as a double-channel sealing structure and has a signal hole. Sealing gasket can be selected according to different fluids and operating temperatures.

Work principle

Fluid A passes from the port on the left of the heat exchanger through every other channel created by the plates to the opposite end port on the left of the heat exchanger (looking at it the long way).

 
Corrosion

Corrosion is usually how these units will fail. Use fluids with reasonable pH levels to ensure a long lasting life. Hard water will corrode faster than regular water. (Use distilled if possible; 

 Application

Refrigeration system
Evaporator
Condenser
Economizer and desuperheaters
Air drier
Heat pump
Absorption chiller
HVAC
Radiant floor

Provide all of the following model
 

D-Sondex Plate Heat Exchanger Model

Detachable Sondex plate heat exchanger specification
Model Connection  surface/plate Plate QTY QMAX Surface max
  DN m2 No. T/H m2
D-S7 50 0.07 76 40 5
D-S14 50 0.15 427 40 59
D-S17 50/65 0.19 609 40 100
D-S18 50/62.5 0.19 609 65 115
D-S21 100 0.22 698 180 146
D-S22 100 0.26 538 165 118
D-S41 150 0.45 670 380 274
D-S42 150 0.46 532 360 223
D-S62 150 0.68 670 380 415
D-S43 200 0.46 695 700 300
D-S65 200 0.68 695 700 450
D-S100 200 1 695 700 695
D-S130 200 1.3 695 700 900
D-S80 300 0.8 930 1600 744
D-S81 300 0.84 930 1600 750
D-S120 300 1.2 930 1600 1115
D-S188 300 1.88 930 1600 1750
300 1.88 930 1600 2210
D-S250 300 2.51 930 1600 2334
D-S200 500 2.06 930 4000 1860
The Table are Sondex Commonly type Pressure Up to 2.5Mpa
Frame type:IS,IT,FT,IG,FS,FG,IC
 
Detailed Photos

Cooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating SystemCooler Heat Exchanger for Air Conditioning Heating System